SDF-Sensors: Averaging pitot tubes for gases and liquids

For accurate flow measurement of gases and liquids

Description

SDF-Sensors use the averaging pitot tube technology and are commonly used where flow rates of gases or liquids are measured. They have been proven in the field to be reliable, stable and accurate for more than 35 years.

Due to the robust technology and the simple principle of measurement, averaging pitot tubes can be used for difficult conditions and offer considerable advantages over other measuring technology from easy installation to long-term measuring stability.

Additional unique advantages are the possibilities of bidirectional flow measurement as well as the integration of temperature and pressure measurement.

Option with FASTLOK Version

With the FASTLOK version, the SDF-Sensor can be inserted or retracted without interrupting plant operation. They are available in four different versions for different pressure ratings and for hazardous gases or atmospheres. The FASTLOK probes can be equipped with a gas-tight packing gland assembly for hazardous fluids and with an integral gear drive for easy insertion/retraction.

SDF-Sensors offer practical advantages wherever

  • a simple, fast and low-cost installation is required,
  • an existing pipeline needs to be retrofitted with a flow meter with minimal installation effort,
  • space is limited with short straight pipe runs,
  • process gas with dust, fibers, corrosive elements or at water saturated conditions need to be measured,
  • operation of a pipeline cannot be interrupted or shutdown during installation,
  • low pressure losses are required for economical or technical reasons.

 

 

Applications

Further information

Product brochure

EN | DE | PT

Installation and operating manual

EN | DE | PT | FR | NL | PL | RU | SL | CZ

Technical information

EN | DE

Our WebApps

The following WebApps offer helpful calculations for selecting and sizing our differential pressure sensors.

Technical specification

Measured quantity: Differential pressure
Optional: Static pressure, Temperature
Measured Fluid: Gases (with dust, water saturated, corrosive) Liquids (low viscosity)
Temperature range: Standard: −50 … 450 °C, optional −180 … 1100 °C
Pressure range: up to PN 320 (flanged) / ANSI #2500
upon request: welded design
Diameter range: DN 25 up to 10000 mm
1" up to 400"
(suitable for rectangular ducts)
Required inlet and outlet pipe straight runs: 7xD inlet, 3xD outlet
Material: Standard: 1.4404 / AISI 316L
Other Options: 1.4541 (AISI 321), 1.4571 (AISI 316Ti), Hastelloy C22 (alloy 22), other materials upon request
Error limit k-factor: ±1% of measured value
Reproducibility: ±0,1 % of measured value
Measurement range: up to 1:40 (in relation to max. flow)